The KYORITSU KEW 2432 is a portable, two-pole leakage clamp meter engineered for rapid, non-intrusive AC leakage and load-current measurements. Encased in a robust housing, it clamps around a single conductorwhether a hot line for load current or multiple conductors excluding a grounded wire for leakage detectionand instantly displays readings on its large LCD.
Internally, the 2432 employs a sequential-comparison system with a WIDE or 50/60 Hz selectable filter to isolate fundamental or high-frequency components. Readings up to 3.999 mA, 39.99 mA, and 80.0 A are rendered with 4 000-count resolution; overrange and low-battery warnings are clearly indicated. A peak-hold mode captures transient events down to 10 ms, useful for inverter-driven loads.
Designed per IEC 61010-2-032 CAT III 300 V, pollution degree 2, the KEW 2432 features tear-drop jaws for cramped cable runs, a glow-in-the-dark TEST button, and audible beeps confirming operation. Auto-power-off after 10 minutes and a backlit display (auto-off after 2 min) conserve two AA cells, ensuring up to 40 hours of continuous use.
| Parameter | Details |
|---|---|
| Measuring Ranges: | 03.999 mA / 039.99 mA / 080.0 A |
| Resolution: | 4 000 counts (max. 3 999 on 2432) |
| Accuracy: | 1.0 %rdg 5 dgt (50 / 60 Hz); 2.5 %rdg 10 dgt (20 Hz1 kHz) |
| Frequency Response: | WIDE or 50/60 Hz (high-cut at 160 Hz, 24 dB/octave) |
| Response Time & Sample Rate: | 2 s response; 2.5 samples/s |
| Power Source: | 21.5 V R03 (UM-4) batteries; 40 h operation |
| Auto-Power-Off: | 10 min after last operation |
| Operating Conditions: | 040 C, 85 % RH; indoor, 2000 m altitude |
| Safety: | IEC 61010-2-032 CAT III 300 V, pollution degree 2 |
| Overload Protection: | 120 A AC max. for 10 s |
| Jaw Capacity: | 40 mm max. conductor |
| Dimensions & Weight: | 1858132 mm; 290 g (incl. batteries) |