Adapter to enable use of other test leads. (MODEL 8259)
| Earth resistance measurement |
1Range | 10 | 100 | |
|---|---|---|---|---|
| Measuring range | 0 to 12 | 0 to 120 | 0 to 1200 | |
| Accuracy | 3% of full scale | |||
| Earth voltage measurement | ||||
| Measuring range | 0 to 30 V AC (50/60Hz) | |||
| Accuracy | 3% of full scale | |||
| Overload protection | Earth resistance : 276V AC/DC (10 seconds) Earth voltage : 276V AC/DC (10 seconds) |
|||
| Applicable standards | IEC 61010-1 CAT 300 V Pollution degree 2 IEC 61010-2-030, IEC 61557-1,5, IEC 60529 (IP54) |
|||
| Power source | R6(AA)(1.5V) 6 | |||
| Dimension | 105(L) 158(W) 70(D) mm (including case lid) | |||
| Weight | Approx. 600g (including batteries and case lid) | |||
| Accessories | 7095A(Earth resistance test leads (Red 20m, Yellow 10m, Green 5m/1set)) 7127B(Simplified measurement probe) 8032(Auxiliary earth spikes[2 spikes/1set]) 9121(shoulder strap) 9084(Carrying case) R6(AA) 6, Instruction manual |
|||
| Optional accessories | 7245A(Precision measurement cord set) 8259(Adapter for measurement terminal) 9164(Carrying case [Hard]) |
IM_4102A_92-1489C_E_L
LC_4102A_4105A_1E